A numerical study has been carried out on a new design of ejector diffuser (infrared suppression device). New design conceptualizes exploiting the shape of the slot openings. A circular arc is provided to guide the entrained fluid at the slot openings. Performance of guided-slot ejector diffuser (GED) has been compared with conventional (non-guided-slot) ejector diffuser (NGED) in terms of local and cumulative mass entrainment ratios, temperature distribution and static pressure recovery. Three slot-area variations are also studied, namely (i) increasing slot-area ranging 1 ≤ A0 ≤ 2.02, ( is area of 1st slot) (ii) constant slot-area A0 = 1 and (iii) decreasing slot-area ranging 0.49 ≤ A0 ≤ 1. Simulations have been carried out at fixed Reynolds number Re = 1.3 105. It is observed that GED has 3.5% higher cumulative mass entrainment ratio than NGED. GED forms cold annulus region below ejector diffuser wall from slot onwards which results in wall temperatures being close to ambient temperature (300 K). Higher mass entrainment rate and lower wall temperatures make GED a better infrared suppression device but static pressure recovery is better in NGED (Cp = 0.79) compared to GED (Cp = 0.43). Slot-area study reveals that the performance of increasing slot-area for GED and NGED is superior then constant and decreasing slot-area configurations. The cumulative mass entrainment is 20% higher while static pressure recovery is 45% more for the increasing slot-area GED when compared to the decreasing slot-area GED.
Singh, L., Singh, S. N., & Sinha, S. S. (2019). Effect of Slot-Guidance and Slot-Area on Air Entrainment in a Conical Ejector Diffuser for Infrared Suppression. Journal of Applied Fluid Mechanics, 12(4), 1303-1318. doi: 10.29252/jafm.12.04.29326
MLA
L. Singh; S. N. Singh; S. S. Sinha. "Effect of Slot-Guidance and Slot-Area on Air Entrainment in a Conical Ejector Diffuser for Infrared Suppression", Journal of Applied Fluid Mechanics, 12, 4, 2019, 1303-1318. doi: 10.29252/jafm.12.04.29326
HARVARD
Singh, L., Singh, S. N., Sinha, S. S. (2019). 'Effect of Slot-Guidance and Slot-Area on Air Entrainment in a Conical Ejector Diffuser for Infrared Suppression', Journal of Applied Fluid Mechanics, 12(4), pp. 1303-1318. doi: 10.29252/jafm.12.04.29326
VANCOUVER
Singh, L., Singh, S. N., Sinha, S. S. Effect of Slot-Guidance and Slot-Area on Air Entrainment in a Conical Ejector Diffuser for Infrared Suppression. Journal of Applied Fluid Mechanics, 2019; 12(4): 1303-1318. doi: 10.29252/jafm.12.04.29326