A Study on Booster Pump System with Flow Sensor for Individual Flow Control Method

Document Type : Regular Article

Authors

1 Department of Mechanical Engineering, International University of Business Agriculture and Technology, Dhaka 1230, Bangladesh

2 School of Mechanical Material Convergence Engineering, Gyeongsang National University, Jinju 52725, South Korea

3 School of Mechanical Engineering, Soongsil University, Seoul 06978, South Korea

4 Sego Industry Pump, Bongsu-daero, Seo-Gu, Incheon, Gyeonggi-do 22845, South Korea

Abstract

Booster pump system (BPS) can control the number of revolutions through an inverter by combining two or more vertical or horizontal centrifugal pumps in a series. Efficiency and energy savings, the most appealing aspects of booster pump systems, can be improved by controlling the operating conditions of individual pumps by measuring the flow rate of each pump. For improved operation, a booster pump system with a flow sensor to detect individual pump flow rates and a control algorithm to manage each low and high flow rate pump’s revolutions per minute are critical. To achieve this, first, the turbine-type flow sensor was developed through computational fluid dynamics and experimentation. The flow sensor was improved using computational fluid dynamics, and its accuracy was validated through experiments. The resulting flow measurement accuracy of the designed flow sensor was within 4%, with a measurement uncertainty of 0.4%. In addition, an experimental pump facility was built and used to evaluate booster pump system performance to investigate the energy saving rate. Then, after driving one low-flow rate pump at a set pressure, the flow and frequency control operation algorithm was used. This algorithm increased the allowed output of the drive pump by increasing the inverter’s frequency. When the frequency corresponding to the allowed output is achieved in the low-flow rate pump rather than the high flow rate pump, power savings increased due to the low-flow rate pump’s extended drive range. The investigations on the developed system’s energy consumption revealed that the energy savings were approximately 6.2% compared to the conventional system, depending on the system in question. The development of a booster pump system with a flow sensor was tested, and it was found to be effective.

Keywords


Angrisani, G., C. Roselli and M. Sasso (2017). Dehumidification and thermal behavior of desiccant wheels: correlations based on experimental and manufacturer data. Heat Transfer Engineering 39(3), 293–303.##
Ansys Inc. 2016, ANSYS-CFX (CFX Introduction, CFX Reference guide, CFX Tutorials, CFX-Pre User's Guide, CFX-Solver Manager User's Guide, Theory Guide), release 16.00, USA.##
Armintor, J. K. and D. P. Connors (1987). Pumping applications in the petroleum and chemical industries. IEEE Transactions on Industry Applications IA-23(1), 37–48.##
Arslan, S. and S. C. Thomas (2002). Grain yield mapping: Yield sensing, yield reconstruction, and errors. Precision Agriculture 3(2), 135–154.##
Asahara, T. (1991). Japan Association of Agriculture Engineering Enterprises, Pumping Station Engineering Hand Book. Tokyo, Japan.##
Bae, C., D. Vuong and H. Lee (2012a). A Study on the pump efficiency measurement using the thermodynamic method. Journal of Korean Society of Marine Environment and Safety 18(3), 267–272.##
Bae, C., D. Vuong and Y. Park (2012b, November). Pump efficiency instrumentation based on thermodynamic method and traditional technique. Int. Conf. on Control, Automation and Information Sciences (ICCAIS), 359–363.##
Bae, Y. S. (2017, December). Flow sensor for booster pump and BPS real-time sensing malfunction. K. R. Patent No. 1018102320000.##
Besse, P. A., G. Boero, M. Demierre, V. Pott and R. Popovi (2002). Detection of a single magnetic microbead using a miniaturized silicon Hall sensor. Applied Physics Letters 80(22), 4199–4201.##
Blazek, J. (2001). Computational Fluid Dynamics: Principles and Applications. 1st Edition, Elsevier, United Kingdom.##
Bryant, J. A. and L. Dennis (1996, May). Effect of a 900 elbow on the accuracy of an insertion flow meter, results and comparisons for 4 and 6 in. diameter pvc pipe. Proceedings of the Tenth Symposium on Improving Building Systems in Hot and Humid Climates, Texas, USA 4(10), 48–59.##
Carlson, R. (2000). The correct method of calculating energy savings to justify adjustable-frequency drives on pumps. IEEE Transactions on Industry Applications 36(6), 1725–1733.##
Chen, Jerry S. J. (2000). On the design of a wide range mini-flow paddlewheel flow sensor. Sensors and Actuators A: Physical 87(1-2), 1–10.##
Deng, H., K. Yang, Y. Liu, S. Zhang and Y. Yao (2021, Aug.). Actively exploring informative data for smart modeling of industrial multiphase flow processes. IEEE Transactions on Industrial Informatics 17(12), 8357–8366.##
Deng, H., Y. Liu, P. Li and S. Zhang (2018). Hybrid model for discharge flow rate prediction of reciprocating multiphase pumps. Advances in Engineering Software.##
Fox, R. W., A. T. Mcdonald, P. J. Pritchard and J. C. Leylegain (2012). Fluid Mechanics. 8th edition, John Wiley and Sons, Inc., (Asia), New Jersey.##
Georgiadis, N. J., D. A. Yoder and W. B. Engblorn (2006). Evaluation of modified two-equation turbulence models for jet flow predictions. AIAA Journal 44(12), 3107–3114.##
JCGM GUM-6 (2020). Guide to the expression of uncertainty in measurementPart 6: Developing and using measurement models, Joint Committee for Guides in Metrology. Available on the web at https://www.bipm.org/en/publications/guides/gum.html##
ISO 5198 (1987) (E), Centrifugal, mixed flow and axial pumps-code for hydraulic performance tests-precision class, International Standard.##
Kaya, D., E. A. Yagmur, K. S. Yigit, F. C. Kilic, A. S. Eren and C. Celik (2008). Energy efficiency in pumps. Energy Conversion and Management 49, 1662–1673.##
Kim, H. H., M. Rakibuzzaman, K. Kim and S. H. Suh (2019). Flow and fast fourier transform analyses for tip clearance effect in an operating kaplan turbine. Energies 12, 264.##
Kim, K. W., S. H. Suh, H. H. Kim, M. Rakibuzzaman and Y. S. Bae (2017, 28 May -1 June), A study on a flow sensor connected with a check valve of a BPS, 10th international conference on computational heat, mass and momentum transfer, Seoul, Korea.##
Kim, K. W., S. H. Suh and M. Rakibuzzaman (2015). Evaluation of energy savings for inverter driving centrifugal pump with duty cycles. The KSFM Journal of Fluid Machinery 18(6), 81–85.##
Kim, S. H., T. J. Nam and S. W. Park (2004). Measurement of flow direction and velocity using a micro machined flow sensor. Sensors and Actuators A: Physical 114(2-3), 312–318.##
KS A 0515 (2006). Method of flow measurement by turbine meters. Seoul, Korea, Korean Agency for Technology and Standards.##
Lee, J. H., K. H. Park and T. H. Hong (2006). Life cycle cost analysis of a general booster pump and high efficiency booster pump. Journal of the Architectectural Institute of Korea Planning & Design 22(9), 259–266.##
Lipej, A. (2021). Flow conditions influence on the instability of a pump characteristic. Journal of Applied Fluid Mechanics 14(4), 1249–1255.##
Menter, F. R. (1994). Two-equation Eddy-Viscosity turbulence models for engineering applications. AIAA Journal 32(8), 1598–1605.##
Moffat, R. J. (1988). Describing the uncertainties in experimental results. Experimental Thermal and Fluid Science 1(1), 3–17.##
Namazizadeh, M., M. Talebian Gevari, M. Mojaddam and M. Vajdi. (2020). Optimization of the splitter blade configuration and geometry of a centrifugal pump impeller using design of experiment. Journal of Applied Fluid Mechanics 13(1), 89–101.##
Rakibuzzaman, M., H. H. Kim, K. Kim, S. H. Suh and K. Y. Kim (2019). Numerical study of sediment erosion analysis in Francis turbine. Sustainability 11, 1423.##
Rakibuzzaman, M., K. W. Kim, H. H. Kim and S. H. Suh (2017). Energy saving rates for a multistage centrifugal pump with variable speed drive. Journal of Power Technologies 97(2), 163–168.##
Rakibuzzaman, S. H. Suh, K. Kim, H. H. Kim, M. T. Cho and I. S. Yoon (2015). A study on multistage centrifugal pump performance characteristics for variable speed drive system. Procedia Engineering 105, 270–275.##
Robinson, J., J. Bryant, J. Haber and D. Turner (1992, May). Calibration of tangential paddlewheel insertion flow meters. Proceedings of the Eighth Symposium on Improving Building Systems in Hot and Humid Climates, Dallas, Texas, USA.##
Ryu, H. S. (1993). Water supply system using booster pumps. Magazine of the SAREK 22(1), 1–16.##
Saidur, R., S. Mekhilef, M. B. Ali, A. Safari and H. A. Mohammed (2012). Applications of variable speed drive (VSD) in electrical motors energy savings. Renewable and Sustainable Energy Reviews 16(1), 543–550.##
Schneider, B. (2005). Selection, operation and control of a work exchanger energy recovery system based on the Singapore project. Desalination 184(1), 197–210.##
Seongwoo, W. and L. Dennis (2006). The effect of elbows on the accuracy of liquid flow measurement with an insertion flow meter. American Society of Heating, Refrigerating and Air-Conditioning Engineers 112(1), 195–201.##
Suh, S. H., Rakibuzzaman, K. W. Kim, H. H. Kim, I. S. Yoon and M. T. Cho (2015). A study on energy saving rate for variable speed condition of multistage centrifugal pump. Journal of Thermal Science 24(6), 566–573.##
Suh, S. H., H. H. Kim, M. Rakibuzzaman, K. W. Kim and I. S. Yoon (2014). A study on the performance evaluation of variable-speed drive pump. The KSFM Journal of Fluid Machinery 17(5), 83–88.##
Taylor, J. R. (1982). An introduction to error analysis. 2nd Edition, University Science Books, Mill Valley, California, USA.##
Urbański, M., M. Nowicki, R. Szewczyk and W. Winiarski (2015). Flowmeter converter based on hall effect sensor. Progress in Automation, Robotics and Measuring Techniques, Springer International publishing, Cham, 352, 265–276.##
Wang, Y., H. Zhang, Z. Han, X. Ni (2021). Optimization design of centrifugal pump flow control system based on adaptive control. Processes 9, 1538.##
Wilcox, D. C. (1994). Turbulence Modeling for CFD. 1st edition, DCW Industries Inc., California, USA.##
Wu, X. F., X. Tian, M. G. Tan and H. L. Liu (2020). Multi-parameter optimization and analysis on performance of a mixed flow pump. Journal of Applied Fluid Mechanics 13(1), 199–209.##
Yogendra, P. J. and M. B. Tadwakar (2014). Implementation of GSM based water meter a step towards automation in billing system. IOSR Journal of Electronics and Communication Engineering 9(1), 1–4.##
Zhou, P., Z. Wu, J. Mou, D. Wu, S. Zheng and Y. Gu (2019). Effect of reflux hole on the transient flow characteristics of the self -priming sewage centrifugal pump. Journal of Applied Fluid Mechanics 12(3), 689–699. ##